What was found
AFT PIT STA 1500 STR 26L FRAME HAS 1 DENT. REMOVED DAMAGE FABRICATED AND INSTALLED RPR PER SRM 53-00-07 RPR 5 TABLE II ZONE 1. RPR IS A CAT B RPR AND REQUIRES SUPPLEMENTAL VISUAL AND NDT INSPECTIONS STARTING AT 50,000 TOTAL FLIGHT CYCLES AND 12,000FC THERE AFTE R. CURRENT FC= 14767.