FIRE LOOP 2 ENG R RIGHT ENGINE FIRE DETECTION SYSTEM LOOP 2 FAILURE. STATUS MSG01, ACTIVE CLIMB INTERMITTENT; FIRE LOOP 2 (RIGHT ENGINE) IS SHORTED. DB- ENGINE FIRE DETECTION CARD (RIGHT) MSG02, ACTIVE CLIMB HARD. ENGINE FIRE DETECTION CARD (RIGHT) HAS AN INTERNAL FAILURE. DB- ENGINE FIRE DETECTION CARD (RIGHT) MSG03, ACTIVE CLIMB HARD; ENGINE FIRE DETECTION CARD (RIGHT) HAS AN INTERNAL FAILURE. ITEM CNX PER PLF SHOWS NOT ACTIVE MSG-2610232 ACTIVE CL INTER MSG-2610012 ACTIVE CL HARD MSG-2610012 ACTIVE CL HARD.