What was found
EICAS ADV MSG DISPLAYED SPOILERS INTERMITTENTLY, MSG 27-11503 FIM TASK 27-61 TASK 821. SUSPECT FAULTY POWER CONTROL UNIT. REPLACED NR 4 SPOILER PCU PER MM 27-61-09. OPS CHECK NORMAL. AC OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EICAS ADV MSG DISPLAYED SPOILERS INTERMITTENTLY, MSG 27-11503 FIM TASK 27-61 TASK 821. SUSPECT FAULTY POWER CONTROL UNIT. REPLACED NR 4 SPOILER PCU PER MM 27-61-09. OPS CHECK NORMAL. AC OK FOR SERVICE.