What was found
AFT PIT STA 1420, STR 25L AND STR 26L, FRAME DENTED. SUPPLEMENTAL DATA UPDATE ACCOMPLISHED MAJOR REPAIR AT GSO. REMOVED DAMAGE, FABRICATED RPR AND INSTALLED IAW SRM 53-00-07. RPR 5 BY MECH 110694 AND INSP BY QC 409 ON NR 20299. THIS IS A CAT B RPR IN ZONE 2 REQUIRING SUPPLEMENTAL INSPECTIONS STARTING AT 25,000 FLT CYCLES AFTER INSTALLATION AND 11,000C THERE AFTER. THESE INSPS ARE BOTH VISUAL AND NDT PER SRM 53-00-07 RPR 5 TABLE II CURRENT PTC IS 20417.