As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM ITEM 255 HAS CORROSION. ACCOMPLISHED MAJOR REPAIR AT DEN. FLOORBEAM ITEM 255 HAS CORROSION. (MARKED) REF SRM 53-41-14 FIG 1 ITEM 255. REMOVED BEAM 255, ON WORK TABLE. CONT OF AMIS ITEM 0912011: PICKED UP HOLES FOR SPLICE ANGLE ON NEW BEAM. CONTINUED WORKING BEAM PART ON TABLE. INSTALLED BEAM 255, NEEDS RIVETS FOR SHEAR PLATE ATTACH INSTALLED. CONTINUED WORKING BEAM. COMPLETED INSTALL OF BEAM 255.