What was found
FOUND CRACKED INTERCOSTAL CLIP S-11L AFT OF STA 294.5, CRACK IN TEE ATTACHMENT ANGLE STR-11L BETWEEN 294.5 & 303.9 STA, CRACK IN CLIP FRAME TO STRINGER S-11 FWD OF STA 294.5, CRACKED INTERCOSTAL WEB S-12L BETWEEN STA 294.5 & 303.9. AND CRACK IN INTERCOSTAL WEB S-16L BETWEEN STA.294.5 AND STA 303.9. MAJOR REPAIR ACCOMPLISHED. AREAS REPAIRED PER REO-L01 076 AND UA-EVA-71613, TO BE REINSPECTED WITHIN 6000C AND EVERY 6000C THEREAFTER. CURRENT PTC 30113. FIRST REINSPECT AT 36113C. PER SB 737-53A1204 (AD 2005-20-03)