As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT FS 1520 STR 26L HAS DENT IN FRAME. ACCOMPLISHED MAJOR REPAIR AT GSO. REPAIRED IAW SRM 53-00-07 REPAIR 5. THIS IS A CAT B REPAIR IN ZONE 1 AND REQUIRES SUPPLEMENTAL INSP STARTING AT 50,000 TOTAL FLT CYCLES PER SRM 53-00-07 RPR 5 TBL II AND 12,000FC THEREAFTER. INSP CONSIST OF BOTH VISUAL AND NDT. CURRENT PTC IS 144 04.