What was found
CORROSION FOUND AT BS 805, LBL 11, UNDER MAIN CABIN FLOOR. *S/D* SUSPECT MOISTURE CONTAMINATION. CUT OUT DAMAGED SECTION OF T-CAP SPLICED IN NEW SECTION PER SRM 53-00-51, SRM 51-20-01 AND SRM 51-40-02. AC OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND AT BS 805, LBL 11, UNDER MAIN CABIN FLOOR. *S/D* SUSPECT MOISTURE CONTAMINATION. CUT OUT DAMAGED SECTION OF T-CAP SPLICED IN NEW SECTION PER SRM 53-00-51, SRM 51-20-01 AND SRM 51-40-02. AC OK FOR SERVICE.