As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT FRAME AT FS 1460 STR 26L HAS DENT. REMOVED DAMAGE FABRICATED AND INSTALLED REPAIR IAW 53-00-07 REPAIR 5 THIS IS A CAT B REPAIR IN ZONE 1 AND REQUIRES S UPPLEMENTAL INSPECTIONS STARTING AT 50000FC AND 12000FC THERE AF TER. INSPS CONSISTS OF BOTH DETAILED VISUAL AND NDT PER SRM 53-0 0-07 RPR 5 TABLE II. CURRENT PTC IS 14404C.