What was found
AFT PIT AT BS 1520, APPROX STR 26L, FRAME HAS DENT AT INBOARD FLANGE. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-07. THIS IS A CAT B RPR IN ZONE 1 AND REQUIRES SUPPLEMENTAL INSPECTIONS STARTING AT 50000FC AND 12000FC THERE AFTER. THIS INSP CONSISTS OF BOTH DETAIL VISUAL AND NDT PER SRM 53-00-07.