As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT AT BS 1480, APPROX STR 26L, FRAME HAS DENT AT INBOARD FLANGE. ACCOMPLISHED MAJOR REPAIR AT GSO. REMOVED DAMAGE, FABRICATED REPAIR AND INSTALLED PER SRM 53-00-07 REPAIR 5. THIS IS A CAT B REPAIR IN ZONE 1 AND REQUIRES SUPPLEMENTAL INSPECTION STARTING AT 50000FC AND 12000FC THEREAFTER PER SRM 53-00-07 REPAIR 5 TABLE II. THESE INSP ARE BOTH DETAIL VISUAL AND NDT CURRENT PTC IS 18040.