What was found
AFT PIT FRAME DENTED STA 1340, STR 25R - 26R. ACCOMPLISHED MAJOR REPAIR AT GSO. REMOVED DAMAGE, FABRICATED REPAIR AND INSTALLED PER SRM 53-00-07 REPAIR 5. THIS IS A CAT B REPAIR IN ZONE 1 AND REQUIRES SUPPLEMENTAL INSPECTION STARTING AT 50000FC AND 12000FC THEREAFTER PER SRM 53-00-07 REPAIR 5 TABLE II. THESE INSP ARE BOTH DETAIL VISUAL AND NDT CURRENT PTC IS 18040.