What was found
AFT PIT FRAME DENTED STA 1440, STR 26L. *S/D* ACCOMPLISHED MAJOR REPAIR AT GSO. CUT OUT DAMAGE AND NDT INSP PER 51-00-19, DAMAGE REMOVED. INSTALLED DOUBLER REPAIR PER SRM 53-0 0-01, REPAIR 5 AND SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT FRAME DENTED STA 1440, STR 26L. *S/D* ACCOMPLISHED MAJOR REPAIR AT GSO. CUT OUT DAMAGE AND NDT INSP PER 51-00-19, DAMAGE REMOVED. INSTALLED DOUBLER REPAIR PER SRM 53-0 0-01, REPAIR 5 AND SRM 51-40-02.