What was found
AFT PIT FRAME DENTED AT INBOARD FLANGE, BS 1420 BETWEEN STR 25L - 26L, 2 PLACES. ACCOMPLISHED MAJOR REPAIR AT GSO. CUT OUT DAMAGE AND INSTALLED DOUBLER RPR PER SRM 53-00-07, RPR 5. CREATED FOR REQUIRED REINSPECTIONS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT FRAME DENTED AT INBOARD FLANGE, BS 1420 BETWEEN STR 25L - 26L, 2 PLACES. ACCOMPLISHED MAJOR REPAIR AT GSO. CUT OUT DAMAGE AND INSTALLED DOUBLER RPR PER SRM 53-00-07, RPR 5. CREATED FOR REQUIRED REINSPECTIONS.