What was found
AFT PIT LT SIDE SLANT AREA HAS DENTED FRAME STA 1580 BETWEEN STR 26L AND 27L. ACCOMPLISHED MAJOR REPAIR AT GSO. CUT OUT DAMAGE AND INSTALLED DOUBLER RPR PER SRM 53-00-07, RPR 5. CREATED FOR REQUIRED REINSPECTIONS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT LT SIDE SLANT AREA HAS DENTED FRAME STA 1580 BETWEEN STR 26L AND 27L. ACCOMPLISHED MAJOR REPAIR AT GSO. CUT OUT DAMAGE AND INSTALLED DOUBLER RPR PER SRM 53-00-07, RPR 5. CREATED FOR REQUIRED REINSPECTIONS.