What was found
ELEC GEN SYS L IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. STATUS MSG01- LATCHED CRUISE MODE DEPENDENT; INTEGRATED DRIVE GENERATOR (L) FREQUENCY IS LOW. DB- GENERATOR CONTROL UNIT (L) MSG-2431631 LATCHED ER MODE. *S/D* SUSPECT FAULTY BEARING. REPLACED IDG IAW MM 24-22-00, OP CHECK GOOD. AC OK FOR SERVICE.