What was found
FLOOR BEAM 205 IS CORRODED (MARKED). *S/D* MAJOR REPAIR ACCOMPLISHED. REMOVED FLOORBEAM 205. REMOVED ANGLES, WORKING ON BENCH. INSTALLED GALLEY ATTACH POINTS, DRILLED NEW SPLICE ANGLES. INSTALLED NEW SPLICE ANGLES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR BEAM 205 IS CORRODED (MARKED). *S/D* MAJOR REPAIR ACCOMPLISHED. REMOVED FLOORBEAM 205. REMOVED ANGLES, WORKING ON BENCH. INSTALLED GALLEY ATTACH POINTS, DRILLED NEW SPLICE ANGLES. INSTALLED NEW SPLICE ANGLES.