What was found
NR 1 PYLON STA 156 WEB AT OUTBOARD DRAIN HOLE IS CRACKED, MIGRATED BEYOND EXISTING STOP DRILL. MAJOR REPAIR ACCOMPLISHED. FOUND 2 CRACKS AT INBOARD DRAIN HOLE. STOP DRILLED CRACKS. FABRICATED & INSTALLED A DOUBLER REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.