What was found
FWD GALLEY OUTBOARD "B" FLOORBEAM HAS ONE FOOT SECTION WITH CORROSION. MAJOR REPAIR ACCOMPLISHED. INSTALLED BRACKETS. INSTALLED MFG'ED BEAM. INSTALLED ALL WIRE BUNDLES AND SECURED ALL CLAMPS BEAM. FINAL INSTALLATION IS COMPLETE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD GALLEY OUTBOARD "B" FLOORBEAM HAS ONE FOOT SECTION WITH CORROSION. MAJOR REPAIR ACCOMPLISHED. INSTALLED BRACKETS. INSTALLED MFG'ED BEAM. INSTALLED ALL WIRE BUNDLES AND SECURED ALL CLAMPS BEAM. FINAL INSTALLATION IS COMPLETE.