What was found
STR 15L AT BS 645 IS CRACKED AT FASTENER HOLE, APPROX 3-16 INCHES IN LENGTH, MARKED. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF STR 15L. INSTALLED SPLICE REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STR 15L AT BS 645 IS CRACKED AT FASTENER HOLE, APPROX 3-16 INCHES IN LENGTH, MARKED. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF STR 15L. INSTALLED SPLICE REPAIR.