SDR 2009F00065

Service difficulty report · Reservoir · Bombdr BD7001A10

Difficulty date
August 17, 2009
Submitted
August 21, 2009
Operation
Air carrier
Aircraft
N400GX
Make and model
Bombdr BD7001A10
Aircraft serial
9037
Aircraft time
4,291 hours, 1,660 cycles
Part
Reservoir
Part number
GX47100129
Part serial
0050
Condition
Failed
Location
Hyd System
Part time
4,291 hours, 1,660 cycles
Stage of operation
CL
How discovered
O
Nature of condition
M, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

APPROX 5 MINUTES INTO DEPARTURE, DURING CLIMBOUT, CREW WAS ALERTED BY AN EICAS MESSAGE "HYD SYS NR 2 OVER TEMP". DECISION WAS MADE TO RETURN TO DEPARTURE. AS THE ACFT DESCENDED, CREW NOTED THE MESSAGE EXTINGUISHED AND THE TEMPS STARTED TO COOL OFF. ACFT MADE AN UNEVENTFUL LANDING AT DEPARTURE. AFTER TROUBLESHOOTING THE HYD SYS NR 2 IT WAS DETERMINED THE HYD SYS NR 2 RESERVOIR WAS DEFECTIVE. THE RESERVOIR WAS REPLACED AND THE ACFT WAS RETURNED TO SERVICE.