Service difficulty report · Pump · Gulstm G100

Difficulty date
December 17, 2009
Submitted
December 17, 2009
Operation
General aviation
Aircraft
N149GA
Make and model
Gulstm G100
Aircraft serial
149
Aircraft time
1,980 hours, 1,357 cycles
Engine
Garrtt TFE73140
Engine time
1,980 hours, 1,357 cycles
Part
Pump
Part number
4018301
Part serial
AL212AB
Condition
Leaking
Location
Hyd System
Part time
293 hours, 207 cycles
Stage of operation
IN
How discovered
V
Nature of condition
K
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DISCOVERED A LARGE AMOUNT OF HYDRAULIC FLUID HAD LEAKED FROM THE RT ENG. FURTHER INVESTIGATION SHOWED A LEAK COMING FROM THE RT HYD PUMP CASE DRAIN INDICATING THAT THE HYD PUMP HAD INTERNALLY FAILED. REMOVED AND REPLACED HYD PUMP, PN 4018301, SN AL212AB IAW AMM 29-10-04, SERVICED HYD IAW AMM 12-10-29, BLEED PERFORMED IAW AMM 29-10-04, OPS CHECKS GOOD IAW AMM 29-10-00.