Service difficulty report · Door · Raythn HAWKER850XP

Difficulty date
February 9, 2010
Submitted
February 16, 2010
Operation
General aviation
Aircraft
N853CC
Make and model
Raythn HAWKER850XP
Aircraft serial
258803
Aircraft time
1,755 hours
Part
Door
Condition
Frozen
Location
Mlg
Stage of operation
AP
How discovered
O
Nature of condition
O
Precautionary procedure
L

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ACFT WAS ON APPROACH. WHEN THE GEAR WAS EXTENDED THE NOSE GEAR DID NOT COME DOWN. THE CREW DIVERTED TO AND AFTER SOME HIGH "G" MANEUVERS GOT THE NOSE GEAR TO EXTEND. THE ACFT MADE A NORMAL LANDING. THE ACFT WAS JACKED AND A GEAR SWING AND INSP WAS PERFORMED. NO PROBLEMS FOUND. THE ACFT WAS REPOSITIONED TO THE SERVICE CENTER FOR A MORE IN DEPTH INSP WITH NO PROBLEMS FOUND. AFTER TALKING WITH THE TECH REP THIS IS A KNOWN PROBLEM WITH THE ACFT AFTER DEPARTING IN MOISTURE AND GOING TO ALTITUDE. IT IS SURMISED THAT MOISTURE GETS IN BETWEEN THE GEAR DOORS AND FUSELAGE AND FREEZES KEEPING THE NOSE GEAR FROM EXTENDING. SOME TESTING WAS PERFORMED AT MFG AND IT WAS DETERMINED THAT A SIX INCH PIECE OF TAPE ACROSS THE NOSE GEAR DOORS COULD KEEP THE NOSE GEAR DOORS FROM EXTENDING. MFG HAS MODIFIED OUR DEPARTURE PROCEDURE IN COLD WEATHER TO TRY AND MITIGATE THIS PROBLEM.