What was found
CORROSION AROUND ATTACH HOLES ON FLOOR SUPPORT PLATE (FITTING) AT FR 58 STR 38 LT. NO CORROSION REMOVAL LIMITS AVAILABLE IN SRM. FITTING IS LISTED AS PRIMARY STRUCTURE. R & R FITTING IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AROUND ATTACH HOLES ON FLOOR SUPPORT PLATE (FITTING) AT FR 58 STR 38 LT. NO CORROSION REMOVAL LIMITS AVAILABLE IN SRM. FITTING IS LISTED AS PRIMARY STRUCTURE. R & R FITTING IAW SRM 51-42-11.