Service difficulty report · Generator · Doug MD9030

Difficulty date
September 29, 2010
Submitted
October 8, 2010
Operation
General aviation
Make and model
Doug MD9030
Part
Generator
Part number
28B5278
Part serial
284
Condition
Damaged
Part time
17,975 hours
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(HZ3R) GENERATOR WAS SEPARATED AT THE END BELL AND STATOR. HELICOILS WERE PULLED. THE MAIN DRIVE SHAFT WAS BROKEN. METAL WAS FOUND IN THE FILTER. THE PUMP WAS SEIZED AND PACKED FULL OF DEBRIS. THE PUMP DRIVE SHAFT WAS IN GOOD CONDITION. THE END BELL EXCITER STATOR WAS LOOSE INSIDE THE ENDBELL, AND AN EXCITER BAND FROM THE ROTOR WAS DISLODGED FROM THE ROTOR AND REMOVED FROM THE END BELL. THE ROTOR HAD SEVERE RUB DAMAGE. THE DRIVE END BAND WAS SEPARATED FROM THE ROTOR. THE OPPOSITE MAIN ROTOR BAND HAD ALSO SLIPPED OUT OF PLACE, BUT WAS STILL ATTACHED TO THE ROTOR. SEVERE RUB DAMAGE TO THE STATOR. CAUSE: ELECTRICAL SHORT IN ROTOR CORE. PREVENTATIVE ACTION: PENDING COMPLETION OF ENGINEERING EVALUATION.