What was found
DURING ENGINE MINOR INSP, SENT OIL FILTER TO LAB FOR ROUTINE ANALYSIS, LAB REPORTED METAL IN OIL. CONTACTED MFG FOR EVALUATION, MFG INSTRUCTED TO INSTALL NEW OIL AND FILTER, PERFORM GROUND RUN FOR 1 HOUR, AND SEND FILTER OUT FOR REPEAT ANALYSIS. SECOND ANALYSIS FOUND MORE METAL (BEARING MATERIAL) IN OIL FILTER. MFG RECOMMENDED ENGINE REPLACEMENT. ENGINE HAS 958.2 HOURS SINCE O/H.