What was found
ACFT AFT VENT BLOWER ASSY REMOVED BEFORE SCHEDULED MAINTENANCE PERIOND. FOUND THAT RESISTORS HAD GONE BAD DURING THE OPS CHECK. REMOVED AND REPLACED RESISTORS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ACFT AFT VENT BLOWER ASSY REMOVED BEFORE SCHEDULED MAINTENANCE PERIOND. FOUND THAT RESISTORS HAD GONE BAD DURING THE OPS CHECK. REMOVED AND REPLACED RESISTORS.