What was found
RT AFT DOOR SILL HAS TWO AREAS OF CORROSION BETWEEN FR 67-68, ST 23-24 AT RBL 56. EXTENT OF DAMAGE IS 1" LENGTH 1.250 WIDTH AND .045" DEPTH. THE SECOND AREA IS 1" LENGTH 1.300 WIDTH AND .066 DEPTH. REPAIRED IAW SRM 53-41-14, FIG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT AFT DOOR SILL HAS TWO AREAS OF CORROSION BETWEEN FR 67-68, ST 23-24 AT RBL 56. EXTENT OF DAMAGE IS 1" LENGTH 1.250 WIDTH AND .045" DEPTH. THE SECOND AREA IS 1" LENGTH 1.300 WIDTH AND .066 DEPTH. REPAIRED IAW SRM 53-41-14, FIG 201.