What was found
PILOT REPORTED ELECTRICAL FAILURE. INSPECTED ACFT, FOUND A/C IDLER PULLEY BEARING SEIZED, CAUSING PULLEY TO COME OFF AND CUT THROUGH SENSOR ALTERNATOR-OUT CONTROL BOX WIRING BUNDLE, CAUSING A/C AND ELECTRICAL POWER TO FAIL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PILOT REPORTED ELECTRICAL FAILURE. INSPECTED ACFT, FOUND A/C IDLER PULLEY BEARING SEIZED, CAUSING PULLEY TO COME OFF AND CUT THROUGH SENSOR ALTERNATOR-OUT CONTROL BOX WIRING BUNDLE, CAUSING A/C AND ELECTRICAL POWER TO FAIL.