What was found
ENGINE WILL NOT PERFORM PROPERLY DURING ENGINE START AND IDLE OPERATION. INSTALLED (4 DEFECTIVE NEW ENGINE DRIVEN FUEL PUMPS (PN 200F-5006) BY THE DIRECTION OF FIELD TECH. FINALLY RECEIVED MFG APPROVAL TO INSTALL A DIFFERENT MFR ENGINE DRIVEN FUEL PUMP O/H PN RG9080J8A/M WHICH FIXED ENGINE HARD STARTING AND ROUGH IDLE OPERATION.