Service difficulty report · Anti-Ice System · Cirrus SR22

Difficulty date
August 20, 2014
Submitted
August 20, 2014
Operation
General aviation
Aircraft
N814BH
Make and model
Cirrus SR22
Aircraft serial
0348
Aircraft time
504 hours
Part
Anti-Ice System
Condition
Restricted
Location
Zone 300
Part time
504 hours
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

IT WAS REPORTED THAT THE ANTI-ICE PANELS ON THE ELEVATOR TIPS WERE NOT FLOWING ON THIS ACFT. THE SYSTEM WAS DISABLED AND THE ACFT CAME TO OUR SERVICE CENTER FOR AN ANNUAL INSPECTION. THE ELEVATOR TIP FLUID FEED LINES WERE FOUND TO HAVE A CREAMY WHITE SUBSTANCE IN THE END OF THE LINES ENTERING THE PANELS THAT PREVENTED FLOW OF FLUID INTO THE PANELS. THERE WAS CONCERN ABOUT CONTAMINATION IN THE REST OF THE SYSTEM. SINCE WE ARE ATTACHED TO THE MFG FACTORY, ARRANGEMENTS WERE MADE TO BRING THE ACFT INTO THE STATION WHERE THE ANTI-ICE SYSTEM IS INSPECTED DURING PRODUCTION AND PERFORM A PRECISE FLOW CHECK. BOTH HORIZONTAL STABILIZER AND THE VERTICAL STABILIZER PANELS FAILED THIS CHECK BY A SIGNIFICANT MARGIN. AN ADDITIONAL CHECK WAS MADE USING A CALIBRATED ORIFICE THAT SIMULATES A PANEL AND IT WAS FOUND THAT THE PUMPS AND FLOW DIVIDERS WERE DELIVERING FLUID IN SUFFICIENT QUANTITY AND PRESSURE TO THE PANELS FOR PROPER OPERATION. IT IS CONCLUDED THAT THE HORIZONTAL AND VERTICAL STABILIZER PANELS WERE ALSO AFFECTED BY THE CONTAMINATION AND THIS RESULTED IN A REDUCTION IN PERFORMANCE. THE AFFECTED PANELS CANNOT BE SALVAGED AND WILL NEED TO BE REPLACED. IT SHOULD BE NOTED THAT WITHOUT A PRECISE MEASUREMENT OF THE FLUID FROM THE PANELS, THEY VISUALLY APPEARED TO "WET OUT" AND FUNCTION NORMALLY. A VISUAL INSPECTION MAY NOT BE SUFFICIENT TO DETERMINE PROPER PANEL OPERATION.

More about the Cirrus SR22