Service difficulty report · Diode · Cirrus SR22

Difficulty date
March 11, 2015
Submitted
March 19, 2015
Operation
General aviation
Aircraft
N822SC
Make and model
Cirrus SR22
Aircraft serial
0899
Aircraft time
3,100 hours
Part
Diode
Part number
J111FCMANDDIODE
Condition
Blown
Location
Electrical
Stage of operation
CR
How discovered
O
Nature of condition
H, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ELECTRICAL FAILURE IN FLIGHT. ALT 2 INDICATION CAME ON, THEN LOW VOLTAGE. LOST AUTOPILOT FIRST, THEN GPS1, THEN MFD, THEN AHARS INFO ON THE PFD. HAD JUST HAD ALT2 OVERHAULED 1 MONTH PRIOR. MADE PARTIAL PANEL IAP AND LANDED SAFELY. AFTER MUCH DIAGNOSIS, THE CAUSE WAS FINALLY DETERMINED. THE TOTAL FAILURE WAS CAUSED BY THE MCU COMPONENTS. ALT 2 FIELD CONTROL MODULE FAILED, RESULTING IN NO VOLTAGE FROM ALT 2 ENERGIZING THE EBUS. THE MAIN POWER DIODE IN MCU FAILURE, WHICH NORMALLY FUNCTIONS SIMILAR TO A BACK-CHECK VALVE, THE POWER DIODE FAILURE DISALLOWED ALT1 FROM ENERGIZING THE ESSENTIAL BUS. PIN J111 IN THE MCU WAS "BURNED" THIS PART IS THE HARDEST CULPRET TO DIAGNOSE, PLEASE CHECK J111 HARNESS CONNECTION PINS AS PART OF THE DIAGNOSIS PROCEDURE. WHEN EBUS WAS ESSENTIALLY ISOLATED, IT DRAINED BATTERY 2 VERY QUICKLY. IN FLIGHT, ON IFR FLIGHT PLAN, THIS WAS ALL INTERPRETED INITIALLY AS A DUAL ALTERNATOR FAILURE, EXCEEDINGLY RARE. IT TURNED OUT THAT BOTH ALT'S WERE GOOD. THE FAILED COMPONENTS WERE ALT2 FCM, POWER DIODE, AND J111 PIN. THE FIELD WIRE TO ALT2 SHOWED FIELD CURRENT WHEN NOT ATTACHED, BUT DROPPED TO ZERO WHEN ATTACHED. THIS CONFUSED THE DIAGNOSIS FOR SOME TIME, BUT ULTIMATELY LINKED BACK TO THE BAD CONNECTION OF THE BURNED J111 PIN.

More about the Cirrus SR22