What was found
WHILE OPENING THE MAIN PAX DOOR, AFTER A FLIGHT, BOTH DOOR SUPPORT CABLES BROKE. IMMEDIATELY AFTER RELEASING THE DOOR LATCH HANDLE AND INITIAL MOVEMENT OF THE DOOR FIRST CABLE BROKE, SPLIT OF A SECOND LATER THE OTHER ONE BROKE AND RELEASE, TOO. MAIN PAX DOOR FELL UNCONTROLLED TO THE FULLY OPEN POSITION AND SUBSTANTIAL DOOR DAMAGE HAS BEEN VISIBLE IMMEDIATELY. THERE WAS NO WAY TO STOP THE DOOR BY ANY MEANS. SUPPORT OF RUBBER CHOKES HAS BEEN PUT ON GROUND IMMEDIATELY AFTER THE OCCURRENCE IN ORDER TO PREVENT ANY FURTHER DAMAGE. MAINTENANCE VISUAL CHECK HAS BEEN DONE TO SEE IF MANUAL CLOSING IS POSSIBLE AND THE ACFT HAS BEEN FERRIED TO OTHER MAINTENANCE FACILITY THE FOLLOWING DAY.