What was found
THE FLIGHT CREW REPORTED THE NR 1 A/C PACK 1 REGULATOR FAULT DISPLAYED ON ECAM DURING CRUISE. REMOVED AND REPLACED COMPRESSOR TEMP SENSOR 12HH IAW AMM 216111. NO FURTHER REPORTS ON SUBSEQUENT FLIGHTS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THE FLIGHT CREW REPORTED THE NR 1 A/C PACK 1 REGULATOR FAULT DISPLAYED ON ECAM DURING CRUISE. REMOVED AND REPLACED COMPRESSOR TEMP SENSOR 12HH IAW AMM 216111. NO FURTHER REPORTS ON SUBSEQUENT FLIGHTS.