What was found
CORROSION FOUND AT L2 DOOR SILL SUPPORT AT FR68, FLOORBEAM Y1732. REMOVED CORROSION REMAINING THICKNESS OUT OF LIMITS. ORIGINAL MATERIAL THICKNESS 0.063, MATERIAL REMOVED 0.030. REMAINING MATERIAL 0.033. FABRICATED REPAIR DOUBLER IAW SRM 534114300001 VIEW F, REPAIR PRINCIPLE 4 SHEET 3 PAGE 6.