Service difficulty report · Actuator

Difficulty date
October 11, 2019
Submitted
October 11, 2019
Operation
General aviation
Part
Actuator
Part number
SFA2325
Part serial
6761
Condition
Failed
Location
Lt Mlg
Part time
72 hours, 50 cycles
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT MAIN GEAR WOULD NOT FREE FALL DURING EMERGENCY EXTENSION. LEFT ACTUATOR WAS INSTALLED NEW AND FAILED AFTER 9 MONTHS OF OPERATION. WHEN DISASSEMBLED IT WAS FOUND THAT THE ACTUATOR ROD WOULD NOT SLIDE IN AND OUT FREELY. IT WAS VERY STIFF. THE INTERNAL SEAL WAS TORN AND BOUND UP THE ROD. THESE ACTUATORS ARE NOT FIELD REPAIRABLE. THE OLD STYLE ACTUATORS WERE AND WOULD LAST FOR YEARS