What was found
AIRCRAFT REPORTED INTERMITTENT ELECTRICAL FAILURES AND OTHER SHOPS HAD REPLACED ALTERNATOR, REGULATOR, AND ALTERNATOR INOP SENSOR WITH NO HELP. FOUND WIRE ON FIELD TERMINAL OF ALTERNATOR SWITCH IN INSTRUMENT PANEL WAS 2 1/2 TURNS LOOSE CAUSING INTERMITTENT CONNECTION WITH REGULATOR.