What was found
ALTERNATOR COOLING FAN ATTACHED TO DRIVE SHAFT SEIZED DURING TAXI CAUSING ALTERNATOR DRIVE SHAFT TO SHEAR AT SHEAR POINT ON ACCESSORY SPLINE. PROBLEM APPEARS TO BE TWO PINS PRESSED INTO COOLING FAN SHROUD WERE PRESSED IN TOO FAR DURING REASSEMBLY AT OVERHAUL. THE PINS CONTACTED FAN AND STOPPED/PREVENTED IT FROM ROTATING. 8130-3 ISSUED BY SOUTHWIND AVIATION AVIATION SUPPLY LLC 5700 N. ROCKWELL, BETHANY, OKLAHOMA 73008 (CERTIFICATE NUMBER: UO9R076Y) FORM TRACKING NUMBER: A49781; WORK ORDER/CONTRACT/INVOICE NUMBE: 49781; DATE: 05/NOV/2021