What was found
THE 1200 HOUR CYCLIC STICK INSPECTION (VISUAL INSPECTION FOR CRACKS IN MOUNTING AREA) WAS PERFORMED IAW THE BHT-407-MPI WITH NO INDICATIONS OF CRACKS SEEN. THE AIRCRAFT MAINTENANCE WAS COMPLETED AND THE AIRCRAFT WAS DELIVERED TO THE CUSTOMER. THE CUSTOMER HAS IMPLEMENTED A DYE PENETRANT INSPECTION DUE TO PREVIOUS ISSUES IN THIS AREA. WHEN THE DYE PENETRANT WAS ACCOMPLISHED AFTER DELIVERY, 2 CRACKS WERE FOUND IN THE INSPECTION AREA THAT WAS PREVIOUSLY INSPECTED WITH NO DEFECTS FOUND.