What was found
DURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA, FOUND L/H PRESSURE PLATE HOLES AT FR 36 HOLE #10 AND #11 CRACKED AT APPROX. 5 O'CLOCK POSITIONS AND HOLE #12 CRACKED AT APPROX. 6 O'CLOCK POSITION. S/O 193146 N/R 20086
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA, FOUND L/H PRESSURE PLATE HOLES AT FR 36 HOLE #10 AND #11 CRACKED AT APPROX. 5 O'CLOCK POSITIONS AND HOLE #12 CRACKED AT APPROX. 6 O'CLOCK POSITION. S/O 193146 N/R 20086