SDR 2023F00240

Service difficulty report · Actuator · Urocop EC135T2

Difficulty date
July 19, 2023
Submitted
July 24, 2023
Operation
General aviation
Aircraft
N442ME
Make and model
Urocop EC135T2
Aircraft serial
1042
Aircraft time
7,602 hours, 40,042 cycles
Part
Actuator
Part number
1646000001
Part serial
00118
Condition
Unknown
Location
Main Rotor Contr
Part time
26,400 hours
Stage of operation
AA
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MAIN ROTOR COLLECTIVE ACTUATOR P/N 1646A0000-01 , S/N 0018 COMPONENT TOTAL TIME 26,400.00 HOURS , TSO 0.0 WAS INSTALLED AT STAT MED EVAC FIXED BASE OPERATION ON AIRCRAFT S/N 1042 AT ACTT : 7602.5. PRIOR TO COMPLETION OF AIRCRAFT MAINTENANCE AND MAINTENANCE GROUND RUNS THE STAT RECORDS DEPARTMENT DISCOVERED THAT THE ACTUATORS HISTORICAL RECORDS SHOWED NO EVIDENCE OF THE AIRBUS MANDATED SERVICE LIFE LIMIT OF 20,000 HOURS BEING COMPLIED WITH. AIRBUS TECHNICAL SERVICES WERE NOTIFIED. AIRBUS WAS UNABLE TO CONFIRM IF THE HOUSING HAD EVER BEEN REPLACED. THE ACTUATOR WAS OVERHAULED AT LIEBHERR - AEROSPACE SALINE, INC AND ARRIVED WITH A VALID FAA FORM 8130-3. THIS COMPONENT WAS ORDERED FROM AIRBUS AND WAS SHIPPED TO STAT FROM AIRBUS USA. STAT MED EVAC REMOVED THE DISCREPANT ACTUATOR PRIOR TO ANY AIRCRAFT STARTS OR OPERATIONS.

More about the Urocop EC135T2