What was found
MECHANICALLY BLENDED LH FUSELAGE PSE SKIN CORROSION LOCATED AROUND LH FWD CABIN WINDOW WITH 1 AREA OF CORROSION, 2ND CABIN WINDOW WITH 1 AREA OF CORROSION, 3RD CABIN WINDOW WITH 5 AREAS OF CORROSION, 4TH CABIN WINDOW WITH 3 AREAS OF CORROSION AND 5TH WINDOW WITH 3 AREAS OF CORROSION IAW C560XL SRM 51-70-08. FOUND 5 CORROSION BLENDS TO BE BEYOND LIMITS IAW C560XL SRM 51-70-08. REPAIRED CORROSION BLENDS IN ACCORDANCE WITH TEXTRON ENGINEERING FIELD REPAIR FR-560-5574-12479 REV- ,