What was found
MECHANICALLY REMOVED 3 AREAS OF CORROSION FOUND AROUND E-EXIT DOOR SKIN AROUND EXTERIOR HANDLE. FOUND 1 CORROSION BLEND TO BE BEYOND LIMITS IAW C560XL SRM 51-70-08. COMPLIED WITH TEXTRON FR-560-5574-12462, TITLE FIELD REPAIR- CORROSION, EMERGENCY EXIT, SKIN, ADJACENT TO HANDLE. DATED 03 OCT 2023, SUPPORTED WITH FAA FORM 8100-9 DATED 03 OCT 2023.