What was found
NLG W/W L/H SUPPORT WEB AT STA 96.00 (REF.) HAS A GOUGE DAMAGE APPROX. 1 1/2 " X 1 1/2". PERFORMED NOSE LANDING GEAR W/W L/H SUPPORT WEB REPAIR AT STA 96.00 I.A.W. DC-9/MD-80 SRM 53-05 FIG.36A. FUTURE MAINTENANCE REQUIREMENT REGARDING THIS REPAIR : VISUAL INSPECTION INITIALLY AT 3,000 CYCLES , FOLLOWED BY REPETITIVE INSPECTIONS EVERY 3,000 CYCLES