What was found
THIS REPAIR STATION RECEIVED 10 PERSON RAFT ASSY. FOR SCHEDULED INSPECTION. THE UNIT DID NOT DEPLOY DURING FLOOR RUN FUNCTIONAL TEST PHASE. THE CHAIN CONNECTOR WAS INCORRECTLY ATTACHED, THE FOLDED/STOWED RAFT WAS MISS RIGGED AT THE LAST OVERHAUL. THIS CONFIGURATION PREVENTING THE UNIT FROM DEPLOYING DURING FLOOR RUN.