As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING DESCENT, HAD MOMENTARILY ELEC ODOR LASTING NO LONGER THAN 30 SECONDS. NO SMOKE OBSERVED. REMOVED AND REPLACED TERMINAL CONNECTORS D3324 AND D3326 FROM WINDOW HEAT TOTB5028 IAW W/D 30-41-11 AND MAN 20-30-00. GROUND TEST NORMAL IAW MM 30-42-00. WIRING CHECK. ACCOMPLISHED IAW 30-41-11, SYS OK. (K)