What was found
UPPER CABIN FLOORBOARD SUPPORT AT FS 1199 TO 1219, RBL 107 FASTENER HOLES CORRODED. (C-CHECK). CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-70-00, FIG 5. REMOVED SEAT TRACK FROM STA 1189-1561 IAW SRM 51-31-01, SEAT TRACK FABRICATED ON TRAVELER NR T9/795690 SPLICES FABRICATED ON TRAVELER NR T9/795686 LOCATED AND DRILLED TRACK AND SPLICES FROM STA 1189- 1561 IAW SRM 53-70-00, FIG 1 AND SRM 51-31-01. TREATED AND PRIMED IAW SRM 51-21-01. INSTALLED SEAT TRACK AND SPLICES STA 1189-1561 IAW SRM 53-70-00 AND SRM 51-31-01.