What was found
LT HYD DECREASED TO ZERO. AFTER LANDING AND ENGINE SHUTDOWN UNABLE TO OPEN LT COCKPIT WINDOW. CRANK SKIPPING FRM 56-11-XA-02. R & R DOWNLOCK ACTUATOR FLEXIBLE HOSE IAW AMM 20-10-10/401. SERVICED LT HYD RESERVOIR IAW AMM 12-12-01/301. SYS OPS CHECKED GOOD, NO LEAKS NOTED. ACCOMPLISHED CAPT'S NR 2 WINDOW INSP IAW AMM 56-11-00/601, NO DAMAGE FOUND. CLEANED AND LUBRICATED TRACK, ROLLERS AND DRIVE SHAFT. NR 2 WINDOW OPS TEST, OK IAW AMM 56-11-02/501.