What was found
DURING DAILY CHECK FOUND EMERGENCY ROW 13, 15, 17 LIGHTS INOP. T/S EMERGENCY LIGHTS AT ROW 13, 15, 17 IAW WDM 33-51-13 FOUND POWER SUPPLY (M1670) BATTERY PACK FAULTY. REMOVED AND REPLACED POWER SUPPLY BATTERY PACK IAW AMM 33-51-06, OPS CHECK NORMAL.