What was found
DURING SCHEDULED ROUTINE MX DISCOVERED CORROSION AT FORWARD SPAR AFT FLANGE BETWEEN STRINGER 15L AND STRINGER 14L. REMOVED CORROSION DAMAGE PERFORMED EDDY CURRENT INSPECTION ON BLEND OUT AREAS NO CORROSION OR CRACKS FOUND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED ROUTINE MX DISCOVERED CORROSION AT FORWARD SPAR AFT FLANGE BETWEEN STRINGER 15L AND STRINGER 14L. REMOVED CORROSION DAMAGE PERFORMED EDDY CURRENT INSPECTION ON BLEND OUT AREAS NO CORROSION OR CRACKS FOUND.